we can easily offer you high-quality products and solutions, competitive rate and very best shopper support. Our destination is "You come here with difficulty and we give you a smile to take away" for Silk Surgical Tape, Luer Lock Syringe, Cpe Shoe Cover, We welcome an prospect to do enterprise along with you and hope to have pleasure in attaching even more aspects of our items.
OEM Famous Latex Medical Examination Gloves Factory – Surgical Gloves: Can they be Re-used? – Jumbo Detail:

Detail

Back in the 1980’s, hospitals around the world used to routinely wash, powder, pack and re-sterilize surgical gloves. Reusable surgical gloves were generally made thicker in order to withstand the strain of reprocessing. However, the more the gloves were re-processed, the less effective they were in preventing cross-contamination, and the less comfortable they became in comparison with recently manufactured gloves. Research has shown that there is a direct relationship between the breakdown of the latex glove barrier and the number of times worn. Although the deterioration of the gloves is not always visible to the human eye, it inevitably occurs with each use. It is risky to rely on the subjective judgment of hospital workers to decide when a surgical glove is no longer a reliable instrument. One of the main problems is that the defective glove may not be obvious to the user. Past surveys have concluded that only 50% of surgical glove punctures are noticed by the wearer. Therefore, it is obvious that the risk of infection to both health worker and patient increases based on how long the surgical glove is worn, especially if the glove is being re-used.

Modern surgical gloves are designed for conditions that are based on the most recent science. They are made out of durable material but are also very thin to ensure that surgeons have full function and sensitivity of their hands. They are also made to be as comfortable as possible to avoid any discomfort during long surgical procedures. These surgical gloves were never intended for over extended use or re-sterilization, and re-used surgical gloves should never be relied on to provide and maintain a strong and sterile barrier for safety.

Functional Benefits

* Extra strength provides additional protection from surgical debris.

* Fully anatomical design to reduce hand fatigue.

* Softness provides superior comfort and natural fit.

* Micro-roughened surface provides excellent wet and dry grip.

* Easy donning and helps prevent rolling back.

* High strength and elasticity.

Quality Standards

* Conforms to ASTM D3577 and EN 455 Standards

* Manufactured under QSR (GMP), ISO 9001:2008 & ISO 13485:2003 (Medical Device) Quality Management System 

* Sterilized by Gamma Ray / EtO

* Bioburden and sterility tested

Glove sizes

5.5, 6.0, 6.5, 7.0, 7.5, 8.0, 8.5, 9.0

Product Specification

Type

Gamma Ray / EtO Sterilized; Powdered

Material

Natural high quality rubber latex

Design & Features

Hand specific; curved fingers; beaded cuff; natural; textured surface; USP grade absorbable cornstarch

Storage

The gloves shall maintain their properties when stored in a dry condition at temperature not higher than 30°C.

Moisture Content

below 0.8% per glove.

Shelf-life   

5 years from the date of manufacturing.

Physical Dimensions

Dimension

Standards

iGlove Glove

ASTM D3577

EN 455

Length(mm)

Min 280

Min 245 (size 5.5) 
Min 265 (size 6-9)

Min. 250 (size 5-5.5) 
Min. 260 size 6-6.5) 
Min. 270 (size 7-8) 
Min. 280 (size 8.5-9.5)

Width(mm) 

• 5.5
• 6.0
• 6.5
• 7.0
• 7.5
• 8.0
• 8.5
• 9.0 

 71 ± 5

77 ± 5

83 ± 5

89 ± 5

95 ± 5

102 ± 5

108 ± 5

115 ± 5

 70 ± 6 

76 ± 6

83 ± 6

89 ± 6

95 ± 6

102 ± 6

108 ± 6

114 ± 6

 72 ± 4 

77 ± 5

83 ± 5

89 ± 5

95 ± 5

102 ± 6

108 ± 6

114 ± 6

Thickness – single wall (mm)

 

 

N/A

Fingers
Palm
Cuff

Min 0.10 
Min 0.10
Min 0.10

Min 0.10 
Min 0.10
Min 0.10

Physical Properties

Property

ASTM D3577

EN 455

Elongation at break (%)

Before Aging
After Aging

min 750
min 560

N/A

Tensile Strength(MPa)

Before Aging
After Aging

min 24
min 18

N/A

Force at Break (N)

Before Aging
After Aging

N/A

Median 9
Median 9


Product detail pictures:

OEM Famous Latex Medical Examination Gloves Factory –  Surgical Gloves: Can they be Re-used? – Jumbo detail pictures

OEM Famous Latex Medical Examination Gloves Factory –  Surgical Gloves: Can they be Re-used? – Jumbo detail pictures

OEM Famous Latex Medical Examination Gloves Factory –  Surgical Gloves: Can they be Re-used? – Jumbo detail pictures


Related Product Guide:

We generally continually give you quite possibly the most conscientious shopper company, and the widest variety of designs and styles with finest materials. These endeavours include the availability of customized designs with speed and dispatch for OEM Famous Latex Medical Examination Gloves Factory – Surgical Gloves: Can they be Re-used? – Jumbo , The product will supply to all over the world, such as: belarus, Azerbaijan, Estonia, Now we've been sincerely consider to grant brand agent in different areas and our agents' maximum margin of profit is the most important thing we care about. Welcome all of the friends and customers to join us. We have been ready to share win-win corporation.
  • Good quality and fast delivery, it's very nice. Some products have a little bit problem, but the supplier replaced timely, overall, we are satisfied.
    5 Stars By Kitty from Myanmar - 2017.08.18 11:04
    It is not easy to find such a professional and responsible provider in today's time. Hope that we can maintain long-term cooperation.
    5 Stars By Althea from Libya - 2017.06.22 12:49
    Write your message here and send it to us